Decode SML-Buffer



IR Data available Bytes read:244
SML_buffer:

1B 1B 1B 1B 01 01 01 01 76 09 14 C0 64 09 00 04 
09 F6 62 00 62 00 72 65 00 00 01 01 76 01 01 09 
00 00 00 00 09 66 18 BB 0B 0A 01 49 54 52 00 03 
49 C9 36 72 62 01 65 09 66 18 BD 01 63 47 37 00 
76 09 14 C0 64 09 00 04 09 F7 62 00 62 00 72 65 
00 00 07 01 77 01 0B 0A 01 49 54 52 00 03 49 C9 
36 07 01 00 62 0A FF FF 72 62 01 65 09 66 18 BD 
74 77 07 01 00 60 32 01 01 01 01 01 01 04 49 54 
52 01 77 07 01 00 60 01 00 FF 01 01 01 01 0B 0A 		Zähler Nr
01 49 54 52  00 03 49 C9 36 01 77 07 01 00 01 08 		kWh Verbrauch
00 FF 65 00 09 29 04 01 62 1E 52 FF 69 00 00 00 
00 07 FC 47 05 01 77 07 01 00 10 07 00 FF 01 01			W Leistung
62 1B 52 00 55 FF FF FF 53 01 01 01 63 6B 26 00 
76 09 14 C0 64 09 00 04 09 F8 62 00 62 00 72 65 
00 00 02 01 71 01 63 DD 0E 00 00 00 1B 1B 1B 1B 
1A 02 1F 98 


meterNo found 1ITR0055167286	hex 03 49 C9 36 
kWh     found 133973765		hex 00 00 00 00   07 FC 47 05 	 	
W       found -173		hex FF FF FF 53





Leistung:
77 07 01 00 10 07 00 ff		Leistung_Summe		*)
77 07 01 00 24 07 00 ff		Leistung_L1	
77 07 01 00 38 07 00 ff		Leistung_L2	
77 07 01 00 4c 07 00 ff		Leistung_L3

Spannung:
77 07 01 00 20 07 00 ff		Spannung_L1,V,Volt_L1,1
77 07 01 00 34 07 00 ff 	Spannung_L2,V,Volt_L2,1
77 07 01 00 48 07 00 ff 	Spannung_L3,V,Volt_L3,1

77 07 01 00 60 01 00 ff		Zählernummer		*)
Verbrauch:
77 07 01 00 01 08 00 ff		Verbrauch		*)
77 07 01 00 02 08 00 ff		Erzeugung

*) gefunden






old:

1B 1B 1B 1B 01 01 01 01 76 09 17 45 9C 06 02 D2
6A 8E 62 00 62 00 72 65 00 00 01 01 76 01 01 09
00 00 00 00 07 8D 13 46 0B 0A 01 49 54 52 00 03
49 C9 36 72 62 01 65 07 8D 13 FD 01 63 9A DF 00
76 09 17 45 9C 06 02 D2 6A 8F 62 00 62 00 72 65
00 00 07 01 77 01 0B 0A 01 49 54 52 00 03 49 C9
36 07 01 00 62 0A FF FF 72 62 01 65 07 8D 13 FD
74 77 07 01 00 60 32 01 01 01 01 01 01 04 49 54
52 01 77 07 01 00 60 01 00 FF 01 01 01 01 0B 0A
01 49 54 52 00 03 49 C9 36 01 77 07 01 00 01 08
00 FF 65 00 08 01 04 01 62 1E 52 FF 69 00 00 00
00 06 F0 06 8B 01 77 07 01 00 10 07 00 FF 01 01
62 1B 52 00 55 00 00 04 30 01 01 01 63 59 B1 00
76 09 17 45 9C 06 02 D2 6A 90 62 00 62 00 72 65
00 00 02 01 71 01 63 10 37 00 00 00 1B 1B 1B 1B
1A 02 99 84

Start


1B 1B 1B 1B                                                     - Start Escape Zeichenfolge
01 01 01 01                                                     - Start Übertragung Version 1

76                                                              - jetzt kommt eine SML-Message
09                                                              - Länge (inkl. Längenbyte)
17 45 9C 06 02 D2 6A 8E
62 00                                                           - groupNo
62 00                                                           - abortOnError

72 65 00 00 01 01                                               - messageBody ?
76 01 01 09
00 00 00 00 07 8D 13 46
0B                                                              - Length
0A                                                              - Lenght
01 49 54 52 00 03 49 C9 36                                      - value 1ITR0055167286
72 62 01 65 07 8D 13 FD 01 63 9A DF 00

76                                                              - jetzt kommt eine SML-Message
09                                                              - Länge (inkl. Längenbyte)
17 45 9C 06 02 D2 6A 8F
62 00                                                           - groupNo
62 00                                                           - abortOnError
72 65 00 00 07 01 77 01
0B                                                              - Length
0A                                                              - Length
01 49 54 52 00 03 49 C9 36                                      - value 1ITR0055167286
07 01 00 62 0A FF FF 72 62 01 65 07 8D 13 FD 74

77 07 01 00 60 32 01 01 01 01 01 01                             - Producer
04                                                              - length
49 54 52                                                        - ITR
01                                                              - End token?

77 07 01 00 60 01 00 FF 01 01 01 01                             - Meter No
0B                                                              - Length
0A                                                              - Length
01 49 54 52 00 03 49 C9 36                                      - value 1ITR0055167286
01

77 07 01 00                                                     - Start SML-Botschaft
01 08 00                                                        - Positive active energy (A+) total [kWh]
FF 65 00 08 01 04 01
62 1E                                                           - kWh Token
52 FF                                                           - Multiplikator
69                                                              - length ?
00 00 00 00 06 F0 06 8B                                         - Integer value
01                                                              - End token?

77 07 01 00                                                     - Start SML-Botschaft
10 07 00 FF                                                     -
01 01
62 1B                                                           - Watt Token
52 00                                                           - MULTIPLIKATOR (see below) optional!
55                                                              - length?
00 00 04 30                                                     - Integer Value = 61072
01 01 01 63 59 B1 00

76                                                              - jetzt kommt eine SML-Message
09                                                              - Länge (inkl. Längenbyte)
17 45 9C 06 02 D2 6A 90
62 00                                                           - groupNo
62 00                                                           - abortOnError

72 65 00 00 02 01 71 01 63 10 37 00 00 00

1B 1B 1B 1B                                                     - Escape
1A                                                              - End of Message
02                                                              - num appended Bytes
99 84


Quellen

OBIS Codes: https://www.promotic.eu/en/pmdoc/Subsystems/Comm/PmDrivers/IEC62056_OBIS.htm Einheiten: ---------- 62 23 für Volt 62 1b für Watt 62 1E für KWh Multiplikator: -------------- 52 fc für 1e-4 52 fd für 1e-3 52 fe für 1e-2 52 ff für 1e-1 52 00 für 1e0 52 01 für 1e1 52 02 für 1e2